Durag d-fl 100 manual

The disc 100 can either be installed close to the sensor at the stack local or on the control room remote. The probe has two separate chambers, between which the flow. The durag dfl 100 velocity measuring system has been suitability tested by tuv nord, test. Suitable systems include the dr 320, dfl 100 and dr 808. Measuring gas velocity with the dfl 100 differential pressure bar. The dfl 100 measuring system operates ac cording to the differential pressure principle. Digital display for optimal adjustment of the flame sensors by measuring the pulse rate and its extreme values d zs 08720set of apertures for insertion in purge air flange d zs 1 set. D r 800 dust concentration meter monitoring solutions. The durag dfl 100 provides a suitabilitytested and certified impact pressure system to measure velocity and volume flow of dry flue gas or process gas in.

Durag product overview emission monitoring ambient monitoring environmental and process data management systems product manual pdf. The dfl 100 20 evaluation unit does not have a display and no control options. The measuring probe has two separate chambers between which the flow builds up a differential pressure. Dfl 100 volume flow measuring system industry mall. The functional diagram for the overall equipment and the device components. Fl 100 measuring system operates according to the mechanical action principle dynamicdifferential pressure measurement with twochamber probe. Dfl 220 a terminal box with an additional panel jack is used. The dfl 100 ams can be used with either the dfl 100 10 evaluation unit or the dfl 100 20 evaluation unit. Durag group d lx110 compact flame monitor easy, versatile and flexible open the catalog to page 1 dlx 110 compact flame monitor easy, versatile and flexible optical flame monitoring housing variants for industrial combustion plants with complex process sequences or several fuels the method of optical flame monitoring often is the most adequate. Dfl 100 probe assembly with assembly of measuring transducer on the probe not for probe 3 dfl 100 hose assembly with the measuring transducer connection via hose line probes probe 1. The new durag dust monitor dr 320 is based on the backscattering principle and is ideally suited for monitoring smallest to medium dust concentrations. The durag dfl 100 measuring system continuously determines the flow velocity. It allows parameterisation and maintenance of all connected devices via integrated keypad or a connected pc and also supports remote access via intranet or internet connection.

Using the auto collimation principle, the light beam traverses the distance to be measured twice. Durag 1107247 durag dzl a122140d1 durag dlx 200 ua1084ex durag dhg 400 cbls1xmp400 durag dug 660 230a 020 durag dr 290 lens for opacity monitor durag z 341 k obsolete, replacement z 341 k2 or z 341 k3 durag 1124089, type dfl 220 ed108l03351. Now in its 2nd generation, the dr 290 is a certified optical transmission monitor to measure the opacity or dust concentration of flue gases with medium to high dust concentrations. The universal display and operating unit disc 100 can be connected to up to 8 durag sensors. Durag product overview emission monitoring ambient monitoring. The durag dr 290 opacity monitor is designed to utilize the principles of light transmission. In situ measurement, continuous measurement allows calibration to measure the volume flow cross duct, half duct and single point versions also suitable for thickwalled stone insulated ducts probe is in contact with sample gas, backpurge as an option automatic zero check as an option universal operation unit disc 100 as an option temperature and pressure sensor as option. Dlx 100 durag group durag group durag group compact flame monitor selfmonitoring and failsafe compact flame monitor for monitoring gas, oil and coal flames with integrated uv, vis or ir flame sensor, primarily in single burner view applications accessories digital display for optimal adjustment of the. D fl 200 compatible followup model remote access possible, digital interface according to vdi 420 operation with or without control unit very low maintenance applications volume flow measuring at low speeds plants with damp andor aggressive exhaust gas, e. The dlx 100 allinone flame scanner consists of a control unit and an optical flame scan control unit and an optical flame scanner. Durag dr 320 dust monitor compliance monitoring products. Suitabilitytested and certified impact pressure system to measure velocity and volume flow of dry flue gas or process gas in pipes or ducts. Dr 290 dust and opacity monitor installation and operation.

Dfl 100 volume flow measuring system industry mall siemens ww. Durag dust monitor dr 320 durag group pdf catalogs. Codel distributor for tunnel monitoring systems in the us. Offering complete cems service and support with parts and repairs.

Dust concentration and opacity monitor of the second generation. Before starting any work please read the operating manual. The durag dr 290 has been used successfully for more than 15 years in various applications as reliable and low maintenance opacity dust monitor. The durag dfl 220 provides a suitabilitytested and certified ultrasonic measuring system to measure the velocity and the volume flow of flue gas or process gas in pipes or ducts, particularly for wet and aggressive smoke emissions. Sale of durag new code 4009428, old code 1108303 4010298. Dlx 720 flame monitor fibre optic software interface. Durag gmbh kollaustrasse 105 22453 hamburg germany tel. The large lc display simultaneously shows up to 4 measuring results. Durag dfl 100 the dfl 100 measuring system operates according to the differential pressure principle. Feb 23, 2021 we specialize in the manufacturing and servicing of continuous emissions monitoring systems cems, continuous opacity monitoring systems coms and compliance stack flow. Dfl 100 volume flow measuring system measuring system to measure flow rate in dry emissions with a probe using the differential pressure principle features measurement of gas velocity calculation of volume flow at standard conditions adjustable parameters automatic back purging device optional. Suitabilitytested and certified impact pressure system to measure velocity and volume flow of dry flue gas or process. This manual is intended to assist you in starting to use your durag product. Please consult the operating manual for further details.

A measuring head is connected via the factoryinstalled ca ble on the terminal box tb fig. Dfl 100 ddmh differential pressure transmitter drx 250 g purge air unit accessories. The dfl 100 measuring system operates according to the di. The probe has two separate chambers between which the flow builds. The transceiver and reflector are mounted opposite one another. The type approval applies to dfl 100 measuring systems from serial number 1230000 onwards. Duragn systems technology a brand of durag gmbh utasll a brand of durag data systems gmbh branch office austria lastenstrage 36, city tower 2 4020 linz, austria tel. Operating manual terminal box dtb 100, dtb 200 durag. Thethe flame scanner is suitable for monitoring flames from a variety of fuels and combustion techniques, particularly in single burner applparticularly in single burner applications. Functional description the dlx 100 flame monitor analyses flame radiation using the integrated flame sensor signal. The evaluation unit dfl 10020 evaluates the measured signal from the differential pressure transducer. The flame intensity is present as a current at one output 04. For mass determination of the pollutants, also the exhaust gas flow must be measured with the help of a measuring device. Aug 09, 2019 s compact design, flame scanner and amplifier built as one unit, therefore, no space is needed the new durag dlx 100 compact flame monitor is the first system of its kind dlx 100 can be adjusted in the field using a manual switch.

In this publication you will find information and technical data for planning, installation commissioning, operation and maintenance of the d. Monitoring solutions continuous emissions monitoring. In situ measurement, continuous measurement allows calibration to measure the volume flow. When we equip emissions monitoring systems, our most commonly chosen flow monitors are the durag dfl 100 and dfl 220. The probe has two separate chambers, between which the. New generation durag dust and volume flow sensors are connected to your stack, monitoring your process. Dfl 100 volume flow measuring system suitabilitytested and certified impact pressure system to measure velocity and volume flow of dry flue gas or process gas in pipes or ducts. Measurement possible below dew point and for high dust concentrations. Dlx 200 flame monitor durag group athex industrial suppliers. Durag recommends to apply the volume flow measuring device dfl 100 and the dust monitor. Dfl 100 volume flow measuring system application according to taluft pollutant emissions of industrial plants must be monitored. This significantly increases the sensitivity of the measurements made by the system.